1.
Sensors (Basel) ; 22(18)2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36146185

RESUMO

The simultaneous measurement of soil water content and water table levels is of great agronomic and hydrological interest. Not only does soil moisture represent the water available for plant growth but also water table levels can affect crop productivity. Furthermore, monitoring soil saturation and water table levels is essential for an early warning of extreme rainfall situations. However, the measurement of these parameters employing commercial instruments has certain disadvantages, with a high cost of purchase and maintenance. In addition, the handling of commercial devices makes it difficult to adapt them to the specific requirements of farmers or decision-makers. Open-source IoT hardware platforms are emerging as an attractive alternative to developing flexible and low-cost devices. This paper describes the design of a datalogger device based on open-source hardware platforms to register water table levels and soil moisture data for agronomic applications. The paper begins by describing energy-saving and wireless transmission techniques. Then, it summarizes the linear calibration of the phreatimeter sensor obtained with laboratory and field data. Finally, it shows how non-linear machine-learning techniques improve predictions over classical tools for the moisture sensor (SKU: SEN0193).


Assuntos
Água Subterrânea , Solo , Calibragem , Água/análise
2.
Data Brief ; 45: 108586, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36164297

RESUMO

Recently, the monitoring of air pollution by means of low-cost sensors has become a growing research field due to the study of techniques based on machine learning to improve the sensors' data quality. For this purpose, sensors undergo a calibration process, where these are placed in-situ nearby a regulatory reference station. The data set explained in this paper contains data from two self-built low-cost air pollution nodes deployed for four months, from January 16, 2021 to May 15, 2021, at an official air quality reference station in Barcelona, Spain. The goal of the deployment was to have five electrochemical sensors at a high sampling rate of 0.5 Hz; two NO 2 sensors, two O 3 sensors, and one NO sensor. It should be noted that the reference stations publish air pollution data every hour, thus at a rate of 2.7 × 10 - 4  Hz. In addition, the nodes have also captured temperature and relative humidity data, which are typically used as correctors in the calibration of low-cost sensors. The availability of the sensors' time series at this high resolution is important in order to be able to carry out analysis from the signal processing perspective, allowing the study of sensor sampling strategies, sensor signal filtering, and the calibration of low-cost sensors among others.

3.
Sensors (Basel) ; 22(10)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35632373

RESUMO

The use of low-cost sensors in conjunction with high-precision instrumentation for air pollution monitoring has shown promising results in recent years. One of the main challenges for these sensors has been the quality of their data, which is why the main efforts have focused on calibrating the sensors using machine learning techniques to improve the data quality. However, there is one aspect that has been overlooked, that is, these sensors are mounted on nodes that may have energy consumption restrictions if they are battery-powered. In this paper, we show the usual sensor data gathering process and we study the existing trade-offs between the sampling of such sensors, the quality of the sensor calibration, and the power consumption involved. To this end, we conduct experiments on prototype nodes measuring tropospheric ozone, nitrogen dioxide, and nitrogen monoxide at high frequency. The results show that the sensor sampling strategy directly affects the quality of the air pollution estimation and that each type of sensor may require different sampling strategies. In addition, duty cycles of 0.1 can be achieved when the sensors have response times in the order of two minutes, and duty cycles between 0.01 and 0.02 can be achieved when the sensor response times are negligible, calibrating with hourly reference values and maintaining a quality of calibrated data similar to when the node is connected to an uninterruptible power supply.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Ozônio , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Monitoramento Ambiental/métodos , Dióxido de Nitrogênio
4.
Data Brief ; 36: 107127, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34095377

RESUMO

The H2020 CAPTOR project deployed three testbeds in Spain, Italy and Austria with low-cost sensors for the measurement of tropospheric ozone (O3). The aim of the H2020 CAPTOR project was to raise public awareness in a project focused on citizen science. Each testbed was supported by an NGO in charge of deciding how to raise citizen awareness according to the needs of each country. The data presented in this document correspond to the raw data captured by the sensor nodes in the Spanish testbed using SGX Sensortech MICS 2614 metal-oxide sensors. The Spanish testbed consisted of the deployment of twenty-five nodes. Each sensor node included four SGX Sensortech MICS 2614 ozone sensors, one temperature sensor and one relative humidity sensor. Each node underwent a calibration process by co-locating the node at an EU reference air quality monitoring station, followed by a deployment in a sub-urban or rural area in Catalonia, Spain. All nodes spent two to three weeks co-located at a reference station in Barcelona, Spain (urban area), followed by two to three weeks co-located at three sub-urban reference stations near the final deployment site. The nodes were then deployed in volunteers' homes for about two months and, finally, the nodes were co-located again at the sub-urban reference stations for two weeks for final calibration and assessment of potential drifts. All data presented in this paper are raw data taken by the sensors that can be used for scientific purposes such as calibration studies using machine learning algorithms, or once the concentration values of the nodes are obtained, they can be used to create tropospheric ozone pollution maps with heterogeneous data sources (reference stations and low-cost sensors).

5.
Sensors (Basel) ; 19(11)2019 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-31159289

RESUMO

New advances in sensor technologies and communications in wireless sensor networks have favored the introduction of low-cost sensors for monitoring air quality applications. In this article, we present the results of the European project H2020 CAPTOR, where three testbeds with sensors were deployed to capture tropospheric ozone concentrations. One of the biggest challenges was the calibration of the sensors, as the manufacturer provides them without calibrating. Throughout the paper, we show how short-term calibration using multiple linear regression produces good calibrated data, but instead produces biases in the calculated long-term concentrations. To mitigate the bias, we propose a linear correction based on Kriging estimation of the mean and standard deviation of the long-term ozone concentrations, thus correcting the bias presented by the sensors.